Skip to content

Charge sustainer charges to the upper threshold at every AC connection, so the lower threshold applies only while AC stays connected #102

Open

Description

@mitar

Device Information

  • Framework Laptop 13 (AMD Ryzen AI 300 Series), Ryzen AI 9 HX 370
  • BIOS 04.02, EC lilac-4.0.2-fdbf549
  • BIOS battery charge limit at 99%, Battery Extender disabled. At 100% the firmware clears the sustainer every second, which wipes thresholds set from the OS (see SoftwareFirmwareIssueTracker#85).
  • Ubuntu 26.04, Linux 7.0, cros_charge_control loaded with probe_with_fwk_charge_control=1. GNOME's Preserve Battery Health (UPower) sets charge_control_start_threshold to 40 and charge_control_end_threshold to 60, which the driver passes to the EC as the sustainer's lower and upper limits.

Issue Description

The sustainer follows the lower threshold only while AC power stays connected. Whenever AC power is connected again, the EC charges the battery up to the upper threshold, whatever the charge, so the lower threshold has no effect on a laptop which is unplugged and plugged in again during the day, for example when it is carried between desks or to a meeting.

Linux documents the start threshold as "a battery percentage level, below which charging will begin". With thresholds 40 and 60, connecting AC power at 45% is expected not to charge. The EC charges to 60% instead.

UPower's charge history from one week shows it at every connection above the lower threshold:

Connected (CET) Charge Result
2026-11-07 21:46 42% charging, up to 60%
2026-11-08 00:20 45% charging, up to 60%
2026-11-08 12:16 48% charging, 60% reached at 12:26
2026-11-10 21:02 59% charging, up to 60%
2026-11-12 14:44 58% charging, until unplugged at 59%
2026-11-12 14:48 58% charging, until unplugged at 59%

While AC power stays connected, the sustainer holds as expected. On 2026-11-08 at 04:09 the battery stayed at 58% without charging, and on 2026-10-22 at 09:09 at 59%.

The same applies to the firmware's own charge limit, which becomes the sustainer window from 5% below the limit up to the limit (as described in #84): every connection tops the battery up to the limit.

Suggested fix

When AC power is connected with the sustainer enabled and the charge between the lower and the upper limit, start the sustainer in CHARGE_CONTROL_IDLE (or CHARGE_CONTROL_DISCHARGE with EC_CHARGE_CONTROL_FLAG_NO_IDLE) instead of CHARGE_CONTROL_NORMAL. Below the lower limit it would charge up to the upper limit, as now. This could be done in process_ac_change() when AC power appears, or as a first evaluation in sustain_battery_soc() after an AC connection.

Activity

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment